Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function

Product Details
Customization: Available
Material: Aluminum
Mounting Type: Outside Mount
Still deciding? Get samples of US$ 500/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
1400 square meters
  • Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
  • Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
  • Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
  • Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
  • Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
  • Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Find Similar Products
  • Overview
  • Product Description
  • Our Advantages
  • Product Parameters
  • Laboratory Testing
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
NCC-01
Privacy Level
High Privacy
Style
Industrial
Transport Package
Wooden Packing
Specification
Size can be ordered according to the situation
Trademark
NCC
Origin
China
HS Code
73083000
Production Capacity
200m2/Month

Product Description

Product Description
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
·NCC Model:
Linear: NSL
Wing curved: NA/NP

·Size:
Thickness: 100mm, 150mm, 200mm, 300mm, 600mm
Size can be customized


·Material:
Galvanized sheet, aluminum sheet, stainless steel sheet, glass fiber wool, etc.
Materials can be customized


·Finish Treatment:
Polyester Powder Coating (PPC)

Any color from the RAL color chart can be chosen

·Other:
Provide stainless steel insect screen
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Model: NSL

Linear louver
NSL-100: 100mm deep
NSL-150: 150mm deep
NSL-150L: 150mm deep
NSL-200: 200mm deep
NSL-300L: 300mm deep
NSL-300: 300mm deep
NSL-600: 600mm deep
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Model: NA, NP

Wing curved louver
NA 300 & NP 300: 300mm deep
NA 600 & NP 600: 600mm deep
Derivative Products
 
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
    Acoustic Louver Door                                           Acoustic Enclosure                                           Acoustic Barrier/Screen

The application scenarios of NCC noise cancelling louvers include:
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Air inlet of ventilation system
                   
Air inlet of outdoor units such as cooling towers Machine room air inlet

HVAC noise reduction
 
Battery energy storage system
noise reduction

Data center vents Water pump room air inlet

Transformer/substation sound insulation room heat sink boiler room

Ventilation louvers for construction machinery radiators

Ventilation openings on soundproof enclosures

Wind turbine vent  

Acoustic louver door for industrial noise reduction

Acoustic enclousure for equipment noise reduction  

Acoustic barrier/screen for cooling tower noise reduction
 
Our Advantages
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
·NCC is the first and currently the only manufacturer in China whose louver series products have passed AMCA (Air Moving and Conditioning (Control) Associationcertification.

·Noise reduction effect, quality commitment, empirical test.

·Fire Certified performance data per ASTM-E84.

·Certified performance data per ASTM E90-09.

·Strong weather resistance, easy to clean and convenient for installation and maintenance.

·Select durable metal types combined with our special surface treatment process can guarantee maximum 20 years service life.

·Model, size, material, ventilation rate, noise reduction decibels, color, etc. can be customized. Our professional design team can provide you with satisfactory solutions.                 
 
Product Parameters

Linear Louver - Sound Transmission Loss (dB)
 

Octave Band
Centre
Frequency,Hz
Louvre
Depth
(mm)
Free area ratio(%) 63 125 250 500 1k 2k 4k 8k STC 
CLASS
NSL-100 100 40-45% 4 5 5 6 10 13 14 14 STC10
NSL-150 150 30-35% 5 6 8 10 14 18 15 14 STC14
NSL-150L 150 50% / 5 6 9 10 12 13 13 STC10
NSL-200 200 28-30% 5 6 8 12 20 16 15 15 STC17
NSL-300L 300 50% / 6 9 11 18 22 21 20 STC14
NSL-300 300 45% 6 7 10 11 17 17 14 13 STC18
NSL-600 600 45% 6 8 11 24 30 33 29 29 STC26
 
 
Wing curved louver - Sound Transmission Loss (dB)
 
Octave Band
Centre
Frequency,Hz
Louvre
Depth
(mm)
Free area ratio(%) 63 125 250 500 1k 2k 4k 8k STC 
CLASS
Model NA300   300 42% 5 6 11 12 12 14 12 10 STC14
Model NA600   600 42% 6 11 15 20 24 27 26 20 STC24
Model NP300   300 50% 4 6 8 10 13 9 7 6 STC11
Model NP600   600 50% 5 10 13 15 22 18 15 13 STC19
 
Laboratory Testing

 NCC Acoustic Laboratory - A Laboratory Professionaly Committed to Serving Customers
         
We exert every ounce of our strength to construct a high-end, avant-garde laboratory endowed with autonomous control capabilities.   For all bespoke products, be it in terms of specifications, dimensions, or acoustic requisites, prior to entering the mass production phase, we shall enforce rigorous and meticulous pre-production sample testing procedures.   Only upon thorough confirmation that all indicators are up to par will we invest a considerable amount of human and material resources to embark on mass production endeavors, thereby effectively guaranteeing that each and every batch of large-scale goods delivered to clients possesses outstanding quality.

 

    The fabricated product samples are positioned within the spacious window of the laboratory and securely fastened through professional sealing measures.   Through precise adjustment of the relevant parameters and concurrent utilization of advanced and precise apparatuses for comprehensive and profound testing, it is ultimately ensured that the products can fully comply with the exacting requirements of customers.
    As depicted in the illustration, the external noise of the laboratory attains 80.1 dB, while through random measurement, the internal acoustic laboratory drops to 36.4 dB or even lower.   The elevated standard of sound insulation not only ensures the accuracy of the experimentation but also furnishes a robust guarantee for the test outcomes.
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
 

· NCC is the first and currently the sole manufacturer in China that our  louver series products have passed AMCA certification.
· All Reports can meet the American Standars, the sound testing we did with Intertek.

Packaging & Shipping

 

Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
 
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
Company Profile
NCC is a supplier of noise control services and acoustic products. We have developed multiple sets of noise control solutions in various fields such as aerospace, commercial buildings, medical audiometry, industrial engineering, power equipment, subways and tunnels, performing arts buildings, and noise reduction laboratories. We provide customers with electric audiometry rooms, semi anechoic rooms, silent rooms, shielded rooms, listening rooms, fireproof soundproof doors, ventilation silencers, exhaust silencers, and noise reduction louvers Comprehensive professional services and technical support for the design, manufacturing, and installation of cooling tower noise control.

Over the years, NCC has developed into a turnkey supplier of noise control, providing customers with one-stop solutions from concept to completion, including solution consulting, synchronous research and development, construction drawing design, structural design, fluid calculation, air conditioning and electrical system engineering, product manufacturing, installation and commissioning, and testing and acceptance services. With over 70 years of experience in noise control and acoustic engineering, we will provide you with solutions that meet your needs and budget. We look forward to working with you.
Customized High Quality Aluminium Soundproof Louvers Used for Ventilation and Noise Control Function
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier