Metal Acoustic Test Facility and Anechoic Chamber

Product Details
Customization: Available
After-sales Service: Yes
Warranty: Yes
Still deciding? Get samples of US$ 200/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
1400 square meters
  • Metal Acoustic Test Facility and Anechoic Chamber
  • Metal Acoustic Test Facility and Anechoic Chamber
  • Metal Acoustic Test Facility and Anechoic Chamber
  • Metal Acoustic Test Facility and Anechoic Chamber
  • Metal Acoustic Test Facility and Anechoic Chamber
  • Metal Acoustic Test Facility and Anechoic Chamber
Find Similar Products
  • Overview
  • Product Description
  • Product Range
  • Product Parameters
  • Laboratory testing
  • Testing Report
  • Our Advantages
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
NCC-11
Type
Absorbing Noise
Open
Closed
Material
Aluminum
Glass Curtain Wall Kind
Acoustic Wedge
Frame Curtain Wall Kind
Hidden Frame
Supporting Construction
Block Construction
Number of Layers
Single
Metal Curtain Wall Kind
Aluminum Honeycomb Panel Curtain Wall
Shape
Wedge
Usage
Interior Wall, Ceiling
Specila Function
Sound-Absorbing
for
Absorption Noise
Scope of Application
Anechoic Room, Reverberation Room, Audiometry Room
Core Material
White, Red, Yellow Glass Fiber Cotton and Polyeste
Fabric Acoustic Split Profile
Fire Proof Cloth
Metallic Acoustic Wedge
Galvanized Sheet, Aluminum Sheet, Stainless Steel
Acoustic Panel Type
Metal Acoustic Panels
Wool Acoustic Panel Type
Groove Wooden Acoustic Panels
Surface Finishing
Woven Fabric, Metal
Transport Package
Wooden Packing
Specification
customized
Trademark
NCC
Origin
China
HS Code
6806900000
Production Capacity
2000 /Month

Product Description

 
Product Description

The principle of gradual transition is applied to make porous (or fibrous) materials into conical or wedge-shaped sound absorbing bodies. When sound waves are incident from the tip, due to the gradual transition property of the sound absorbing layer, the sound resistance of the material can match well, allowing the sound waves transmitted to the sound absorbing body to be effectively absorbed.

Metal Acoustic Test Facility and Anechoic Chamber
Metal Acoustic Test Facility and Anechoic Chamber



NCC Boheng Fabric Splitting, using fire-resistant cloth to wrap the splitting bracket, filled with soundproof cotton inside, can absorb medium to high sound frequencies.The internal filling materials of the fabric cutting edge include yellow standard cotton, white formaldehyde free glass cotton, environmentally friendly fiber cotton, etc; It is more widely used in various laboratories, with a service life of about 30 years. When the service life is reached, it can be purchased separately at a lower cost, and its sound reception effect has greater advantages compared to other acoustic product

 
Metal Acoustic Test Facility and Anechoic Chamber
Sound absorbing cotton filling

The interior is filled with sound absorption and insulation material, and adopts reasonable structure to absorb sound waves.
 
Fabric wedge

The use of fireproof cloth, noise suppression and fire prevention, and moderate weight, easy to install on the wall and ceiling.
Metal Acoustic Test Facility and Anechoic Chamber
Metal Acoustic Test Facility and Anechoic Chamber
Metal wedge

Usually used galvanized steel plate and aluminum alloy plate, and the use of non-woven cloth wrapped sound-absorbing cotton, dirty and durable, long service life.
Wedge mounting structure 

Sound wedge generally has a certain thickness of the base, easy to install, and easy to achieve the best sound absorption effect, generally sound wedge and the wall will leave some gaps, forming a cavity, will make the cutoff frequency is lower.
Metal Acoustic Test Facility and Anechoic Chamber


 

Metal Acoustic Test Facility and Anechoic Chamber
Staggered arrangement 

Increase the absorption area of sound waves, so that the sound waves incident on it are almost completely absorbed without reflection, and the main use is to build a full anechoic chamber and a semi-anechoic chamber.

 

Product Range

 

• Construction of sound absorption structure necessary for precision anechoic chamber.

• Used to test the electroacoustic parameters of electroacoustic products.

• All kinds of machinery, mechanical and electrical, light industry, household appliances and other products noise measurement.

• Scientific experiments on speech acoustics, music acoustics, psychoacoustics, and sound propagation.

• A wide band of high efficiency sound absorption characteristics including low frequencies is obtained, and the cutoff frequency of anechoic chamber can generally reach 60-70 Hz.

• The specific specifications of the acoustic wedge are determined by the cut-off frequency to be absorbed.
Metal Acoustic Test Facility and Anechoic Chamber

 

Product Parameters

Model: 400*400*600

Frequency(Hz) 100 125 160 200 250 315 400
Absorption coefficient 0.998 0.992 0.988 0.997 0.992 0.997 0.998

Model: 400*400*300

Frequency(Hz) 100 125 160 200 250 315 400
Absorption coefficient 0.708 0.909 0.974 0.983 0.967 0.965 0.993

Model: 1200* 1200*1200mm

Frequency,Hz 40 50 63 80 100 125 160 200 250
Absorption Coefficient 0.696 0.893 0.993 0.994 0.998 0.997 0.994 0.998 0.998

• Sound absorbing wedge is a kind of special sound absorbing structural material for strong sound absorbing field, the use of porous (or fibrous) material molding cutting, made into a cone or wedge sound absorber, firm without deformation.

• Sound absorption wedge is suitable for strong airflow environment, the main object is high-quality anechoic chamber, the absorption of low frequency is more effective, can eliminate standing waves, to eliminate the requirements of echo, low cut-off frequency sound absorption coefficient greater than 0.99.

• The sound insulation wall of the anechoic chamber is installed with an anechoic wedge, which can form a smooth layer connection, so that the uncertainty and irregularity of noise acoustic wave reflection can be extended, and the sound absorption performance of the anechoic chamber can be improved.

• Compared with ordinary acoustic wedge, the V-shaped and W-shaped acoustic wedge made of polyester has the characteristics of smaller occupancy volume and more reasonable price.


For each individual project, it is possible to select a panel design which has the required sound transmission loss and sound absorption ratings. 
 

Laboratory testing

  NCC Acoustic Laboratory - A Laboratory Professionaly Committed to Serving Customers

         We exert every ounce of our strength to construct a high-end, avant-garde laboratory endowed with autonomous control capabilities.   For all bespoke products, be it in terms of specifications, dimensions, or acoustic requisites, prior to entering the mass production phase, we shall enforce rigorous and meticulous pre-production sample testing procedures.   Only upon thorough confirmation that all indicators are up to par will we invest a considerable amount of human and material resources to embark on mass production endeavors, thereby effectively guaranteeing that each and every batch of large-scale goods delivered to clients possesses outstanding quality.

 The fabricated product samples are positioned within the spacious window of the laboratory and securely fastened through professional sealing measures.   Through precise adjustment of the relevant parameters and concurrent utilization of advanced and precise apparatuses for comprehensive and profound testing, it is ultimately ensured that the products can fully comply with the exacting requirements of customers.
    As depicted in the illustration, the external noise of the laboratory attains 80.1 dB, while through random measurement, the internal acoustic laboratory drops to 36.4 dB or even lower.   The elevated standard of sound insulation not only ensures the accuracy of the experimentation but also furnishes a robust guarantee for the test outcomes.
Metal Acoustic Test Facility and Anechoic Chamber
Metal Acoustic Test Facility and Anechoic Chamber
Metal Acoustic Test Facility and Anechoic Chamber

 

Testing Report

All Reports can meet the American Standars, the sound testing we did with Intertek
 

Metal Acoustic Test Facility and Anechoic Chamber

Our Advantages

NCC acoustic equipment includes a variety of fields, structural sound insulation equipment, while shielding the environment from unnecessary noise according to user requirements.

Our louvres are available in an array of standard modular sizes, meaning that a wide range of performance requirements can be met. By using our range of acoustic louvres, it overcomes architectural consistency issues, especially where space is limited. 

Other product specifications

 (to be customized)

1200MM

1200*1200*1200mm

1200*1200*1450mm

1200*1200*1150mm

1000MM

1000*1000*800mm

1000*1000*700mm

600MM

600*600*600mm

Packaging & Shipping

All our packing with Rubber clip board,don't need to do fumigation.
 

Metal Acoustic Test Facility and Anechoic Chamber
Metal Acoustic Test Facility and Anechoic Chamber
Company Profile
NCC is a supplier of noise control services and acoustic products. We have developed multiple sets of noise control solutions in various fields such as aerospace, commercial buildings, medical audiometry, industrial engineering, power equipment, subways and tunnels, performing arts buildings, and noise reduction laboratories. We provide customers with electric audiometry rooms, semi anechoic rooms, silent rooms, shielded rooms, listening rooms, fireproof soundproof doors, ventilation silencers, exhaust silencers, and noise reduction louvers Comprehensive professional services and technical support for the design, manufacturing, and installation of cooling tower noise control.

Over the years, NCC has developed into a turnkey supplier of noise control, providing customers with one-stop solutions from concept to completion, including solution consulting, synchronous research and development, construction drawing design, structural design, fluid calculation, air conditioning and electrical system engineering, product manufacturing, installation and commissioning, and testing and acceptance services. With over 70 years of experience in noise control and acoustic engineering, we will provide you with solutions that meet your needs and budget. We look forward to working with you.
Metal Acoustic Test Facility and Anechoic Chamber


          

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier