Silencer Air Duct

Product Details
After-sales Service: Yes
Warranty: 1years
Customized: Customized
Still deciding? Get samples of US$ 200/Square Meter
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
1400 square meters
  • Silencer Air Duct
  • Silencer Air Duct
  • Silencer Air Duct
  • Silencer Air Duct
  • Silencer Air Duct
  • Silencer Air Duct
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Our Advantages
  • Product Parameters
  • Laboratory Testing
  • Certifications
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
NCC-13
Material
Galvanized Steel, Aluminum, Stainless Steel
Color
Customization
Shape
Rectangle, Cylinder
Open Mouth
Customization
for
Pipe Muffling
Transport Package
Silencer)
Specification
Customization
Trademark
NCC
Origin
China
HS Code
7308900000
Production Capacity
2000

Product Description


 
Product Description

NCC rectangular and cylindrical pipe silencers provide more effective, accurate and economical noise reduction solutions compared to other noise reduction methods, because all NCC products are derived from strict laboratory and field tests. In addition, NCC-made pipe silencers strictly control manufacturing tolerances and the use of noise reduction materials to achieve stable noise reduction effects.

Silencer Air Duct
Silencer Air Duct


Suitable for the most common occasions - passing noise is generated by air flow. This series of low-cost design units are easy to install and suitable for air flow in any direction. It can effectively stop noise in both directions.

 
Detailed Photos
Silencer Air Duct
Silencer Air Duct
Silencer Air Duct
Silencer Air Duct

 

Our Advantages

NCC can provide acoustic solutions to solve environmental noise problems in mixed commercial/residential areas. It can provide all related noise acoustic analysis, ventilation pressure loss calculation, product structure verification, air and fluid simulation services.
Over the years, the continued success of our products and services has enabled the NCC brand to earn a consistent reputation for quality and performance among a wide range of customers, be they multinationals or independent family businesses. This is due to the expertise and passion of our Boheng people, as well as the excellence of our products.

Silencer Air Duct
NCC Silencing Air Duct is a necessity in air handling systems. The emergence of high-performance HVAC equipment has led to unacceptable low-frequency and high-frequency noise pollution, which has created a need for stricter noise control in air conditioning systems. High-performance mufflers offer the most effective and economical solution, and air handling component manufacturers provide more reliable noise data. Therefore, using silencers accurately rated under operating conditions helps achieve the required noise standards. NCC's silencing air ducts are rated under the working conditions of the most advanced acoustic research and development laboratory. Regardless of its size or configuration, our silencing air ducts are developed, tested, and rated in accordance with the latest industry standards.

Effective noise reduction
It can significantly reduce the noise generated during the operation of the air duct system, providing a quiet and comfortable indoor environment.
Improve air quality
While reducing noise, it does not affect the normal circulation of air, ensuring a good ventilation effect and thereby improving indoor air quality. 
Energy-saving and efficient
The optimized air duct design reduces wind resistance and lowers the energy consumption of the fan, helping to save energy costs.,
Strong stability
It has good compression and deformation resistance capabilities and can maintain good performance and shape during long-term use.
Good fire performance: Made of fireproof materials, it can prevent the spread of fire to a certain extent and improve the fire safety of buildings.
Long service life
High-quality materials and excellent manufacturing processes give it a long service life, reducing the frequency of replacement and maintenance.

Product Parameters

NCC Acoustics' silencers are rated under the working conditions of state-of-the-art acoustic research and development laboratories.  Regardless of its size or configuration, our silencers are developed, tested, and rated according to the latest industry standards.

Page Silencer Type Face Velocity Self Noise(Lw) DIL,dBat250Hz Pressure
opinN/m²
Length(mm) Length(mm)
m/s dB 900 1500 2100 3000 900 3000
16 NFS 5 45 22 31 37 47 142 177
18 NFM 5 36 15 23 30 39 47 60
20 N 3 35 15 23 31 41 90 122
22 NSM 3 31 14 21 29 38 50 78
24 NES 5 33 14 19 31 41 55 110
26 NMS 5 36 12 17 23 32 25 47
28 NFL 5 32 14 17 22 29 20 25
30 NML 5 30 9 14 19 25 12 22
32 NL 5 37 8 13 16 23 12 17

 

Laboratory Testing

NCC Acoustic Laboratory - A Laboratory Professionaly Committed to Serving Customers

      We exert every ounce of our strength to construct a high-end, avant-garde laboratory endowed with autonomous control capabilities.   For all bespoke products, be it in terms of specifications, dimensions, or acoustic requisites, prior to entering the mass production phase, we shall enforce rigorous and meticulous pre-production sample testing procedures.   Only upon thorough confirmation that all indicators are up to par will we invest a considerable amount of human and material resources to embark on mass production endeavors, thereby effectively guaranteeing that each and every batch of large-scale goods delivered to clients possesses outstanding quality.

  The fabricated product samples are positioned within the spacious window of the laboratory and securely fastened through professional sealing measures.   Through precise adjustment of the relevant parameters and concurrent utilization of advanced and precise apparatuses for comprehensive and profound testing, it is ultimately ensured that the products can fully comply with the exacting requirements of customers.
    As depicted in the illustration, the external noise of the laboratory attains 80.1 dB, while through random measurement, the internal acoustic laboratory drops to 36.4 dB or even lower.   The elevated standard of sound insulation not only ensures the accuracy of the experimentation but also furnishes a robust guarantee for the test outcomes.
Silencer Air Duct
Silencer Air Duct
Silencer Air Duct
 
Certifications

Silencer Air Duct
Packaging & Shipping
Silencer Air Duct
Silencer Air Duct
 
Silencer Air Duct
Silencer Air Duct
 

 

Company Profile
 
Silencer Air Duct
NCC is a supplier of noise control services and acoustic products. We have developed multiple sets of noise control solutions in various fields such as aerospace, commercial buildings, medical audiometry, industrial engineering, power equipment, subways and tunnels, performing arts buildings, and noise reduction laboratories. We provide customers with electric audiometry rooms, semi anechoic rooms, silent rooms, shielded rooms, listening rooms, fireproof soundproof doors, ventilation silencers, exhaust silencers, and noise reduction louvers Comprehensive professional services and technical support for the design, manufacturing, and installation of cooling tower noise control.

Over the years, NCC has developed into a turnkey supplier of noise control, providing customers with one-stop solutions from concept to completion, including solution consulting, synchronous research and development, construction drawing design, structural design, fluid calculation, air conditioning and electrical system engineering, product manufacturing, installation and commissioning, and testing and acceptance services. With over 70 years of experience in noise control and acoustic engineering, we will provide you with solutions that meet your needs and budget. We look forward to working with you.
Silencer Air Duct
Silencer Air Duct


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now