Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports

Product Details
After-sales Service: Yes
Warranty: 1years
Customized: Customized
Still deciding? Get samples of US$ 280/Square Meter
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
1400 square meters
  • Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
  • Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
  • Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
  • Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
  • Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Our Advantages
  • Product Parameters
  • Laboratory testing
  • Certifications
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Certification
ISO
Type
Sound Insulation Cover
Application
Ventilation Silencer
Material
Galvanized Steel, Aluminum, Stainless Steel
Color
Customization
Shape
Rectangle, Cylinder
Open Mouth
Customization
for
Pipe Muffling
Transport Package
Silencer)
Specification
Customization
Trademark
NCC
Origin
China
HS Code
7308300000
Production Capacity
2000 M2/Month

Product Description

Product Description

NCC is a leading manufacturer of noise cancelling louvers worldwide, with sturdy, durable, and high-performance products that have been applied multiple times worldwide. The application scenarios of NCC noise cancelling louvers include:

• Air inlet of ventilation system     
       

  Air inlet of outdoor units  such as cooling towers

• Machine room air inlet                           

• Data center vents 

• Water pump room air inlet   
             

• Transformer/substation sound insulation room heat sink boiler room

Ventilation louvers for construction machinery radiators

Ventilation openings on soundproof enclosures

Wind turbine vent 

Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports


 

We can provide acoustic louvre solutions to combat environmental noise problems in mixed commercial / residential areas, carrying out all relevant noise surveys and acoustic analysis.
 

Detailed Photos

Our acoustic louvred screens result in a high performance solution to unwanted levels of noise, without the need for additional architectural cladding.
 

Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
 
Our Advantages

NCC acoustic louvres are multi-purpose, permitting air to flow, whilst shielding the environment from unwanted noise.

Our louvres are available in an array of standard modular sizes, meaning that a wide range of performance requirements can be met. By using our range of acoustic louvres, it overcomes architectural consistency issues, especially where space is limited. 
 

1,Rugged all-steel galvanised construction. Stainless steel, aluminium
and other materials are also available.

2,Inert, vermin-proof, weather-rated non combustible acoustic fill.

3,Shaped splitter blade for maximum noise reduction with minimum pressure drop.

4,Perforated splitter underside for maximum sound absorption.

5,Weather stop inhibits rain/snow entry.

6,300mm deep single banked systems and 600mm deep for the double banked system.

7,Available in a variety of durable, attractive finishes,such as  vinyl coated steel, polyester powder paint, anodised aluminium,  galvanised and stainless steel.

8,Modular sizes enable assembly of rectilinear louvre 'walls' of almost any size.

9,Louvre blade orientation blocks horizontal line of site, enhancing both aesthetics and acoustic performance.

10,Bird guards are available in galvanised or stainless steel, insect screens can also be supplied.
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
 
Product Parameters

Silencer--Sound Transmission Loss(dB)         

 
Page Silencer Type Face Velocity Self Noise(Lw) DIL,dBat250Hz Pressure
opinN/m²
Length(mm) Length(mm)
m/s dB 900 1500 2100 3000 900 3000
16 NFS 5 45 22 31 37 47 142 177
18 NFM 5 36 15 23 30 39 47 60
20 N 3 35 15 23 31 41 90 122
22 NSM 3 31 14 21 29 38 50 78
24 NES 5 33 14 19 31 41 55 110
26 NMS 5 36 12 17 23 32 25 47
28 NFL 5 32 14 17 22 29 20 25
30 NML 5 30 9 14 19 25 12 22
32 NL 5 37 8 13 16 23 12 17
 
Laboratory testing

         NCC Acoustic Laboratory - A Laboratory Professionaly Committed to Serving Customers
         
We exert every ounce of our strength to construct a high-end, avant-garde laboratory endowed with autonomous control capabilities.   For all bespoke products, be it in terms of specifications, dimensions, or acoustic requisites, prior to entering the mass production phase, we shall enforce rigorous and meticulous pre-production sample testing procedures.   Only upon thorough confirmation that all indicators are up to par will we invest a considerable amount of human and material resources to embark on mass production endeavors, thereby effectively guaranteeing that each and every batch of large-scale goods delivered to clients possesses outstanding quality.

 The fabricated product samples are positioned within the spacious window of the laboratory and securely fastened through professional sealing measures.   Through precise adjustment of the relevant parameters and concurrent utilization of advanced and precise apparatuses for comprehensive and profound testing, it is ultimately ensured that the products can fully comply with the exacting requirements of customers.
    As depicted in the illustration, the external noise of the laboratory attains 80.1 dB, while through random measurement, the internal acoustic laboratory drops to 36.4 dB or even lower.   The elevated standard of sound insulation not only ensures the accuracy of the experimentation but also furnishes a robust guarantee for the test outcomes.
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
 
Certifications

Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports

Packaging & Shipping

All our packing with Rubber clip board,don't need to do fumigation.
 

Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
 
Company Profile
 
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
NCC is a supplier of noise control services and acoustic products. We have developed multiple sets of noise control solutions in various fields such as aerospace, commercial buildings, medical audiometry, industrial engineering, power equipment, subways and tunnels, performing arts buildings, and noise reduction laboratories. We provide customers with electric audiometry rooms, semi anechoic rooms, silent rooms, shielded rooms, listening rooms, fireproof soundproof doors, ventilation silencers, exhaust silencers, and noise reduction louvers Comprehensive professional services and technical support for the design, manufacturing, and installation of cooling tower noise control.

Over the years, NCC has developed into a turnkey supplier of noise control, providing customers with one-stop solutions from concept to completion, including solution consulting, synchronous research and development, construction drawing design, structural design, fluid calculation, air conditioning and electrical system engineering, product manufacturing, installation and commissioning, and testing and acceptance services. With over 70 years of experience in noise control and acoustic engineering, we will provide you with solutions that meet your needs and budget. We look forward to working with you.
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports
Icon Tower’ S Noise Solution: American-Standard Mufflers at Ventilation Duct Ports



 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier