| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | 2years |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency






Acoustic louver | |||||||||
Octave Band Centre Frequency,Hz | Louvre Depth (mm) | 63 | 125 | 250 | 500 | 1k | 2k | 4k | 8k |
NSL-100 | 100 | 4 | 5 | 5 | 6 | 10 | 13 | 14 | 14 |
NSL-150 | 150 | 5 | 6 | 8 | 10 | 14 | 18 | 15 | 14 |
NSL-150L | 150 | / | 5 | 6 | 9 | 10 | 12 | 13 | 13 |
NSL-200 | 200 | 5 | 6 | 8 | 12 | 20 | 16 | 15 | 15 |
NSL-300L | 300 | / | 6 | 9 | 11 | 18 | 22 | 21 | 20 |
NSL-300 | 300 | 6 | 7 | 10 | 11 | 17 | 17 | 14 | 13 |
NSL450 | 450 | 5 | 6 | 11 | 19 | 21 | 22 | 24 | 23 |
NSL-600 | 600 | 6 | 8 | 11 | 24 | 30 | 33 | 29 | 29 |
Model NA300 | 300 | 5 | 6 | 11 | 12 | 12 | 14 | 12 | 10 |
Model NA600 | 600 | 6 | 11 | 15 | 20 | 24 | 27 | 26 | 20 |
Model NP300 | 300 | 4 | 6 | 8 | 10 | 13 | 9 | 7 | 6 |
Model NP600 | 600 | 5 | 10 | 13 | 15 | 22 | 18 | 15 | 13 |
Ventilation Duct Silencer | ||||||||
Silencer Type | Face Velocity | Self Noise(Lw) | DIL,dBat250Hz | Pressure opinN/m2 | ||||
Length(mm) | Length(mm) | |||||||
m/s | dB | 900 | 1500 | 2100 | 3000 | 900 | 3000 | |
NFS | 5 | 45 | 22 | 31 | 37 | 47 | 142 | 177 |
NFM | 5 | 36 | 15 | 23 | 30 | 39 | 47 | 60 |
N | 3 | 35 | 15 | 23 | 31 | 41 | 90 | 122 |
NSM | 3 | 31 | 14 | 21 | 29 | 38 | 50 | 78 |
NES | 5 | 33 | 14 | 19 | 31 | 41 | 55 | 110 |
NMS | 5 | 36 | 12 | 17 | 23 | 32 | 25 | 47 |
NFL | 5 | 32 | 14 | 17 | 22 | 29 | 20 | 25 |
NML | 5 | 30 | 9 | 14 | 19 | 25 | 12 | 22 |
NL | 5 | 37 | 8 | 13 | 16 | 23 | 12 | 17 |
Acoustic Panel | ||||||||
Model | Centre Frequency,Hz | 125 | 250 | 500 | 1k | 2k | 4k | NRC* |
NVT-50 (50mm) | Coefficient | 0.35 | 0.65 | 1.20 | 1.21 | 1.07 | 0.92 | 1.00 |
NVT-100 (100mm) | Coefficient | 0.97 | 1.39 | 1.34 | 1.29 | 1.19 | 1.01 | 1.30 |
Acoustic Door | |||||||
Door Mode | Sound-Lock M-50 | Sound-Lock M-53 | Sound-Lock M-54 | Sound-Lock M-61 | Sound-Lock M-64 | ||
Acoustic Rating | RW | 49 | 52 | 53 | 59 | 63 | |
R'W | 45 | 48 | 48 | 59 | 61 | ||
STC | 50 | 53 | 54 | 61 | 64 | ||
NIC | 46 | 48 | 49 | 56 | 59 | ||
Leaf Thickness | 70mm | 70mm | 90mm | 90mm | 127mm | ||
Octave Band Centre Frequency | 63 | Sound Transmission Loss,dB | 21 | 22 | 24 | 24 | 25 |
125 | 27 | 31 | 32 | 35 | 35 | ||
250 | 37 | 45 | 52 | 56 | 56 | ||
500 | 40 | 52 | 54 | 58 | 60 | ||
1k | 44 | 53 | 52 | 60 | 65 | ||
2k | 42 | 54 | 52 | 60 | 67 | ||
4k | 45 | 58 | 61 | 68 | 70 | ||
8k | 48 | 63 | ≥61 | 73 | 75 | ||
Weight | 58kg/m2 | 60kg/m2 | 65kg/m2 | 80kg/m2 | 86kg/m2 | ||
For acoustic performence<50dB, pleace see NCC Acoustics'range of Sound-Lock Doors. | |||||||


Application Scenarios and Typical Uses of Acoustic Enclosures: | |
Industrial Equipment Noise Reduction | For industrial equipment such as generators, air compressors, cooling towers, fans, and punch presses-devices that produce high-frequency or high-decibel noise-acoustic enclosures form a closed wrap around the equipment, effectively blocking noise from spreading outward. This not only complies with the relevant noise emission standards in the factory area but also provides reliable protection for the hearing health of operators. |
Precision Instrument Protection | In application scenarios such as semiconductor testing equipment, laboratory analytical instruments, and medical imaging devices, acoustic enclosures can isolate external environmental noise and prevent it from interfering with the precise measurement or operational stability of the instruments. |
Commercial and Public Spaces | It is suitable for building supporting equipment such as air conditioning units and pump rooms, and can reduce noise interference to surrounding office areas and residential communities. It can also be used to build temporary acoustic barriers around concert halls and recording studios to isolate ambient noise from the external environment. |







