Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver

Product Details
Customization: Available
Application: Classroom, Home Theater, Office Meeting Room, Recording Studio, Restaurant
Color: Gray
Still deciding? Get samples of US$ 200/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
1400 square meters
  • Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
  • Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
  • Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
  • Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
  • Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
  • Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
Find Similar Products
  • Overview
  • Product Description
  • Our Advantages
  • Product Parameters
  • Laboratory testing
  • Certifications
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
NCC-06
Environmental Certification
E1
Fire Rating
Class A
Installation Method
Interlocking Panels
Pattern
Square
Warranty
3 Years
Open Type
Immobilization
Kind
Louver
After-Sales Service
Yes
Transport Package
Wooden Packing
Specification
Size can be ordered according to the situation
Trademark
NCC
Origin
China
HS Code
73083000
Production Capacity
200/Month

Product Description

Product Description

 

Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver

NCC is a leading global manufacturer of multi-function louvers.It's a  rugged, high-performance product and  used many times and years around the world.

The product NCC Rainproof Louver is used in ventilation projects.

Transformer substation sound insulation room, radiator, boiler room.

Ventilation louvers for radiators in construction machinery.

Air intake air intake in the data center.

Water pump room air intake.

The vent on the soundproof enclosure.

Fan vent.

Ventilation system Air intake Air intake for outdoor units such as cooling towers.

Rain-proof shutter is a kind of shutter structure used to prevent wind and rain intrusion, it is composed of a plurality of shutter pieces, can effectively block wind and rain, protect the indoor safety and indoor environment.

 
Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
 
NCC louvers can be made into sound-absorbing louvers with single or double leaf structures, with a minimum structural height of 850mm.

The standard height for single leaf doors is 1250mm x 3000mm, and the height for double leaf doors is 2500mm x 3000mm


All doors are equipped with joint locks, latches, and handles

Soundproof doors can be provided with bird guards and insect nets upon request

The door can be provided with polyester powder coating

Can be made of galvanized steel, stainless steel, or aluminum.

 

 

 
Our Advantages
Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
 
The main characteristics and advantages of NCC acoustic louvers are:

Equipped with weather resistant sealing plates to prevent the infiltration of rain and snow

The modular design can make the louvers suitable for use with any size of "vent"

It can serve as an independent barrier around equipment or be integrated with building walls

The horizontal arrangement of the silencing louvers not only reflects aesthetics, but also enhances rain and waterproof performance

It can be equipped with stainless steel or galvanized bird nets, as well as insect nets

Meet anti-theft requirements and standards.

 

Product Parameters

The double row shutters FYL155S series are rated A for high rainwater permeability and are rated 2 for airflow rate and airflow class.

Single row blinds FYL100S, series with good airflow rate and airflow grade of 2.

All NCC rain blinds get the  Chinese GB test reports. Free area calculations can be provided based on the size of the shutter segment for each item.

 

Model FYL155S FYL100S
Blade type Single Single
Blade deep 155mm 100mm
Blade direction Horizontal Horizontal
Rainwater infiltration
(Air flow velocity, units:M/S)
0 / C
0.87 B C
1 C C
1.5 C C
2 C C
2.5 C C
3 C D
3.5 C D
Airflow coefficient 0.395 0.39
Air flow level 2 2
Air flow rating good good


NCC's anechoic louver has an energy-efficient aerodynamic design and a very low pressure drop characteristic. The sturdy all metal structure ensures a long service life for NCC's noise reduction louvers. If necessary, we can also provide necessary supporting steel structures and provide comprehensive installation services.

For each individual project, it can be adjusted according to site conditions, as well as environmental factors.

 
Laboratory testing


NCC Acoustic Laboratory - A Laboratory Professionaly Committed to Serving Customers

         
We exert every ounce of our strength to construct a high-end, avant-garde laboratory endowed with autonomous control capabilities.   For all bespoke products, be it in terms of specifications, dimensions, or acoustic requisites, prior to entering the mass production phase, we shall enforce rigorous and meticulous pre-production sample testing procedures.   Only upon thorough confirmation that all indicators are up to par will we invest a considerable amount of human and material resources to embark on mass production endeavors, thereby effectively guaranteeing that each and every batch of large-scale goods delivered to clients possesses outstanding quality.
 

The fabricated product samples are positioned within the spacious window of the laboratory and securely fastened through professional sealing measures.   Through precise adjustment of the relevant parameters and concurrent utilization of advanced and precise apparatuses for comprehensive and profound testing, it is ultimately ensured that the products can fully comply with the exacting requirements of customers.
    As depicted in the illustration, the external noise of the laboratory attains 80.1 dB, while through random measurement, the internal acoustic laboratory drops to 36.4 dB or even lower.   The elevated standard of sound insulation not only ensures the accuracy of the experimentation but also furnishes a robust guarantee for the test outcomes.
Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver

 

Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver

 


 
Certifications

Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver

Packaging & Shipping
Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver

 

Company Profile

 

Ncc Building Material Supply Company Process Air Intakes for Rainproof Louver
NCC is a supplier of noise control services and acoustic products. We have developed multiple sets of noise control solutions in various fields such as aerospace, commercial buildings, medical audiometry, industrial engineering, power equipment, subways and tunnels, performing arts buildings, and noise reduction laboratories. We provide customers with electric audiometry rooms, semi anechoic rooms, silent rooms, shielded rooms, listening rooms, fireproof soundproof doors, ventilation silencers, exhaust silencers, and noise reduction louvers Comprehensive professional services and technical support for the design, manufacturing, and installation of cooling tower noise control.

Over the past few years, NCC has developed into a turnkey supplier of noise control, providing customers with one-stop solutions from concept to completion, including solution consulting, synchronous research and development, construction drawing design, structural design, fluid calculation, air conditioning and electrical system engineering, product manufacturing, installation and commissioning, and testing and acceptance services. With over 70 years of experience in noise control and acoustic engineering, we will provide you with solutions that meet your needs and budget. We look forward to working with you.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier